5 Easy Facts About cytometer Described
5 Easy Facts About cytometer Described
Blog Article
At the moment, the early signals had been dismissed as debris, but the retrospective evaluation shown shared characteristics While using the problematic cells in culture. Tracing the infection assisted the lab create more laboratory strategies for screening and defense of assay-crucial mobile traces.
As samples are obtained over the Attune CytPix Flow Cytometer, the high-speed brightfield camera captures and retailers illustrations or photos of detected events at a fee nearly 6,000 visuals for every next, according to the flow amount and graphic sizing. For bigger versatility, Attune Cytometric Application permits you to adjust the image capture frequency as necessary and choose a certain gate for impression seize, if expected.
Blend acoustic focusing technologies with significant-parameter Examination for flexible spectral unmixing and conventional workflows.
Uncover new insights into your experimental data by visualizing populations using combined fluorescence and morphology knowledge. Our software program interface wizards empower downsampling, concatenation (merged documents) and dimensionality resources which are developed into your software program for an intuitive, streamlined info Examination knowledge.
*Pricing is indicative only and is particularly issue to vary. Please Make contact with your Agilent consultant with any thoughts. The knowledge set forth herein just isn't an offer or simply a dedication, both of those of which can be subject matter to credit history approval, stipulations, and availability with Agilent. Agilent Monetary Remedies is available in picked nations.
Listed here, a highly skilled user has gated singlets confidently. Just after analyzing the guide singlet gate, the CytPix image-derived parameter ParticleCount reveals this gate incorporates in excess of four% aggregates.
Optimizing gating tactic. Even sturdy manual singlet gating is error-susceptible and remains a subjective choice level in Practically all flow cytometry assays. Imaging may be used to confirm and adjust gates to incorporate only solitary cells of curiosity.
Steady impression top quality even at large throughput Acoustic focusing plus a substantial-pace digital camera Incorporate to picture these T cells continuously at small or substantial flow fees. Quickly alter concentrate and camera configurations to fulfill experimental needs.
Early signs of this contamination experienced at first been dismissed as particles. Backgating to discover new populations. Backgating imaged cells about the Attune CytPix Flow Cytometer also permits you to use morphological capabilities to find out appealing subpopulations that could not be apparent from flow cytometry information on your own.
Users can perspective event visuals in real-time to confirm sample excellent, improve protocols, and history the morphology of each cell inhabitants recognized for analysis. Imaging seize also Rewards from acoustic concentrating, which really helps to placement the cells in order that a sharp, centered graphic is attained.
Seem waves help precise cell alignment, causing Fantastic info top quality and check here ~10X quicker sample flow prices.
We Formerly demonstrated the power of imaging Motor vehicle-T/Ramos cell interactions. Enable’s look at just the population of biggest fascination, the double good activities, To find out more. We will now use extended morphological parameters (right here, circularity and skewness of intensity) to further more study the capabilities of those populations and refine gating on these events, growing details robustness.
Designed-in dimensionality reduction equipment greater resolution into populations. Fluorescently gated populations back-gated on to UMAP plot to verify envisioned population resolution in lysed entire human blood. Consumer can see activities from each cluster for visual affirmation of cell phenotypes.
No clean/no lyse leukocyte analysis with imaging. Cells were acquired from 24-hour-outdated blood by dilution in one mM EDTA ( Professional UX/UI enables customers to practice AI types for expanded apps. (A) The “Practice Model” function supplies annotation tools and authentic-time product coaching accuracy.
At the heart of each Attune Flow Cytometer lies our groundbreaking acoustic concentrating technological know-how, which makes use of sound waves to meticulously align cells throughout the flow cell. This impressive solution surpasses regular hydrodynamic strategies, causing a lot quicker processing speeds, Extraordinary data high-quality, and improved sample throughput.
The Attune Xenith cytometer is actually a substantial-parameter spectral analyzer, delivering each spectral unmixing and conventional flow abilities for thorough and versatile cell Assessment.
Agilent Price Assure ensures you at least ten years of instrument use through the date you purchase. Or else, We are going to credit score you Along with the residual value of the system towards an upgraded model.
What gave the impression to be a homogeneous population is really extra various—an insight that should be thought of when interpreting results.